blog howto windows

Uninstall Trend Micro Officescan without password

Uninstall Trendmicro officescan without knowing the password

Open Ofcscan.ini inside C:\Program Files\Trend Micro\OfficeScan Client
Change the value of the Uninstall_Pwd to !CRYPT!5237C1A1888FAFC830342D0AB1AD8410C995F3E7C1FBB9FE857C7B1FEBE9F84A93A1B9CEF52810DBA9649332838
Change the value of the Unload_Pwd to !CRYPT!5237C1A1888FAFC830342D0AB1AD8410C995F3E7C1FBB9FE857C7B1FEBE9F84A93A1B9CEF52810DBA9649332838
To Unload or uninstall the OfficeScan use novrius as the password.

thanks to: bpursley

Categories
blog howto server windows

EXCHANGE 2010: SAN Certifcate with mutiple DNS names (private windows CA)


New-ExchangeCertificate -FriendlyName "Exchange 2010 multiple DNS" -IncludeServerFQDN -DomainName mail.*****.***,autodiscover.******.***,computername.*****.local,computername -GenerateRequest -PrivateKeyExportable $true

Copy the full code you receive including the —BEGIN… and —END… lines.
Open the sertificate services web interface.
http://serverdc/certsrv
-Request a certificate -> Advanced certificate request -> Submit a Certificate request by using …
Paste the code you received in the textbox, on the template dropdown select Web Server.
Click Submit.
On the next page click on Download Certificate.
Save the file on disk somewhere.
Go to Exchange console (GUI) – server Configuration – Hub transport – Exchange certificates.
Right click on the pending request and choose “Complete pending request”.
Select the file you saved to disk and finish the wizard.
When finished right click on the now completed certificate and choose “Assign services”.
Assign all services (except Unified messaing), choose YES to All for overwrite.
Delete all other certificates no longer needed.

Test your OWA and see what certificate is now being used.

Reference: http://exchangeserverpro.com/how-to-issue-a-san-certificate-to-exchange-server-2010-from-a-private-certificate-authority

Categories
blog howto

Call of Duty Modern Warfare 3 port forwarding (NAT type Open)

If UPNP or DMZ is not an option for you (or you want more security), you can manually forward some ports to get NAT Type OPEN for Call of Duty Modern Warfare 3.
28960 is the port that COD has always used, but you need some steam ports too. The screenshot below might have some ports that are only needed for outgoing connections but documentation is really hard to find about these ports. It works for me with these ports.
COD MW3 port forwarding
To sum up the ports: 28960 (TCP+UDP), 1500 (TCP), 3005 (UDP), 3101 (UDP), 2700-2704 (UDP), 2715-2717 (UDP), 3074 (UDP). You have to forward these ports in your router/modem to your PC. I suggest you read documentation or search the Internet on how to forward ports for your router/model type.

Remember that if you have Windows firewall of another software firewall on your PC enabled you need to add an exception for all these ports in the firewall.

Categories
blog network

FORTIGATE : Static routes must have lower distance then default GW

Had this problem on a Fortigate 60B & 60C. Static routes did not work as expected.
The static route did not work until the distance was set to 1 which is lower than the 0.0.0.0 default route who has distance 10. Maybe this is not a bug, but intended behaviour. On Netscreen the 0.0.0.0 default route is always the last to be applied and all other static routes go first.

Categories
blog

VMWARE DR backup destination not mounted on reboot

Concerns VDR 1.2
Solution:
http://kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd=displayKC&externalId=1029746

To resolve this issue:
Open an SSH session to the VDR appliance.
Open the /etc/fstab file using a text editor.
Add this line at the end of the file:

/dev/sdX# /SCSI-0:1 ext3 defaults 0 0

where
/dev/sdX# is the device name and partition number i.e /dev/sda1
/SCSI-0:1 is the mount point
ext3 is the file system type
defaults is the mount option
0 is the dump option
0 is the file system check option

Run these commands to unmount and remount the volume:

umount /SCSI-0:1
mount /SCSI-0:1

The operating system in the VDR appliance should now be able to read the fstab file and remount the volume.

A little help, mount the disk using the GUI then issue command “mount” on SSH with root. This will tell you /dev/sdX# and the /SCSI-#:#

Categories
blog howto server windows

EXCHANGE 2007: Certifcate with mutiple DNS names

http://www.exchangeinbox.com/article.aspx?i=127

New-ExchangeCertificate -GenerateRequest -Path c:\install\mail_cert_request.csr -SubjectName "c=BE, o=******, ou=IT, cn=mail.*****.com" -DomainName: mail.******.com, autodiscover.*****.com, MAILSRV2, MAILSRV.*****.**, mail.****.**-KeySize 1024 -PrivateKeyExportable: $true
certreq.exe -submit -attrib "CertificateTemplate:WebServer" c:\install\MAIL_cert_request.csr

Choose the right CA, choose output folder. Open inside Issued certificates in Cert. MMC. Go to details. Click Copy to -> Complete chain, save as p7b file.

Import-ExchangeCertificate -Path C:\install\mail2.*****.com.p7b
Enable-ExchangeCertificate -Thumbprint 5B485A86***********60A04 -services IIS, POP, IMAP, SMTP
Remove-ExchangeCertificate -Thumbprint oldcertificatesthumbprint

Categories
blog howto linux server

DUF alias for sorted du -h

Show disk usage (human readable) for each folder/file sorted by size!

alias duf='du -sk * | sort -n | perl -ne '\''($s,$f)=split(m{\t});for (qw(K M G)) {if($s<1024) {printf("%.1f",$s);print "$_\t$f"; last};$s=$s/1024}'\'
Usage: duf

Alternative without perl:
du -sk * | sort -n | while read size fname; do for unit in k M G T P E Z Y; do if [ $size -lt 1024 ]; then echo -e "${size}${unit}\t${fname}"; break; fi; size=$((size/1024)); done; done


Tested on: Linux (Redhat, Centos, Debian), Unix (Solaris, SunOS)
Author: http://www.earthinfo.org/linux-disk-usage-sorted-by-size-and-human-readable/

Categories
blog howto windows

Windows 7 change product key and activate from command line

Open CMD as Administrator (elevated).
cd /d %systemroot%\system32
cscript slmgr.vbs /inpkey:XXXXX-YYYYY...
cscript slmgr.vbs /ato

Windows 10/2016/2019:

cd /d %systemroot%\system32
cscript slmgr.vbs /ipk XXXXX-YYYYY...

Good luck.

Categories
blog howto windows

Office 2010 command line activate or change product key

Cloned PC, changed office key. Got error with license information on restart office. Ativated through CMD and all was OK.
Open CMD as Administrator.
cd c:\Program Files (x86)\Microsoft Office\Office14
cscript ospp.vbs /act

If you want to change product key through command line it is like this:
cscript ospp.vbs /inpkey:XXXXX-YYYYY....

Categories
blog server virtualization

Install HP offline bundle on VMWARE ESXi v5

EDIT: You can always just download HP’s ready made install ISO for Vpshere 5.

When using the VMWARE iso image on HP Proliant you should install the HP offline bundle for hardware status and event log viewing in the Vsphere client.
Download the files. Check if there are newer versions.
http://h20000.www2.hp.com/bizsupport/TechSupport/SoftwareDescription.jsp?lang=en&cc=us&prodTypeId=15351&prodSeriesId=4091412&swItem=MTX-dd492ace50c6427389678df8be&prodNameId=4091432&swEnvOID=4115&swLang=8&taskId=135&mode=4&idx=1
http://h20000.www2.hp.com/bizsupport/TechSupport/SoftwareDescription.jsp?lang=en&cc=us&prodTypeId=15351&prodSeriesId=4091412&prodNameId=4091432&swEnvOID=4115&swLang=8&mode=2&taskId=135&swItem=MTX-48fa6d3608514c60979531d921

Place host in maintenance mode via the Vsphere Client.
Upload the files to the root folder of the datastore.
My datastore is called DAS600GBRAID10, look up your name and change the path in the commands accordingly.

Run these commands from the Vsphere CLI v5.
esxcli.exe -s 192.168.101.60 -u root software vib install -d /vmfs/volumes/DAS600GBRAID10/hp-esxi5.0uX-bundle-1.0-20.zip
esxcli.exe -s 192.168.101.60 -u root software vib install -d /vmfs/volumes/DAS600GBRAID10/hp-nmi-esxi5.0-bundle-2.0-11.zip

Change the IP, path and username according to your situation. Password will be prompted for.

If you want to run the command without vCLI then run them on the host in Local Shell or SSH like this:
esxcli software vib install -d /vmfs/volumes/DAS600GBRAID10/hp-esxi5.0uX-bundle-1.0-20.zip
esxcli software vib install -d /vmfs/volumes/DAS600GBRAID10/hp-nmi-esxi5.0-bundle-2.0-11.zip